Skip to main content Skip to search Skip to main navigation

ALLNET / ALL-LAN-ISO-4kV, Gigabit LAN Isolator/PoE Blocker 4kV ALL-LAN-ISO-4kV

Product information "ALLNET / ALL-LAN-ISO-4kV, Gigabit LAN Isolator/PoE Blocker 4kV ALL-LAN-ISO-4kV"

Key features:

  • Gigabit Ethernet (10/100/1000 Mbit/s)
  • IEEE 802.3ab compliant
  • 4 kVrms dielectric strength
  • Electrical isolation: creepage distance: 12.8 mm, clear distance: 12.2 mm
  • no restrictions on cable length
  • ESD protection: Suppression of transient overvoltages on signal lines
  • Suitable for devices with a supply voltage of up to 250 Vrms
  • Not suitable for use with PoE devices
  • Dimensions 80x58x24mm

Plug & Play – no installation required

Compact and universally applicable

No permanently fitted cables

Robust housing

Suitable for all systems with a network connection

Requires no power supply

APPLICATIONS:


EQUIPMENT PROTECTION
Protection of particularly valuable equipment against hum and overvoltages from network peripherals.

MEASUREMENT TECHNOLOGY
Protection of electrical measurement and monitoring equipment against external and interference voltages from the
Ethernet cabling.

POTENTIAL DIFFERENTIALS (BUILDING SERVICES)
Prevention of equipotential bonding currents in computer systems that are galvanically connected to one another over long distances via Ethernet
cabling.

AUDIO
Reduction of low-frequency alternating voltages (mains hum) caused by the network connection to a level that is no longer perceptible.

Robust housing

suitable for all systems with a network connection

requires no power supply

Technical Details:

Dielectric strength of signal and shielding 5,000 V 50/60 Hz for 1 min; 10,000 VDC for 10 s
Data throughput 10/100/1000 Mbit/s
Connections 2x RJ45 input/output
Network specifications IEEE 803.2 from 10/100/1000-BaseT, twisted pair, auto-configuration (behaves completely transparently within the network)
Material UL94V-0/RoHS-compliant/SvHC/REACH
Product Rating (UL) Passive electronic components, insulation class DI (250 VAC/300 VDC) tested at 4 kVAC
Operating mode Continuous operation
Mean time between failures 0.21 × 108 (1 failure in 21,000,000 h)
ESD 16 kV
DC stress test (10 s) 10 kV
Return loss min. 10 dB
Insertion loss max. 1.3 dB
Dimensions (mm, LxWxH) 80 x 58 x 24, approx. 39 g
Standards IEC 60601-1 1x MOPP up to 250 Vrms (the built-in mains transformer)
Environment

Operating: -10°C ~ +75°C
Storage: -20°C ~ +75°C
10% ~ 85% relative humidity (non-condensing)